Inverter vs. conventional generators

Once you know what size you need, the next decision is type. The two work the same way mechanically — an engine spins an alternator — but they deliver very different electricity.

What "clean power" actually means

A conventional generator's output voltage and frequency wobble with engine speed. An inverter generator takes the raw AC, converts it to DC, then inverts it back to a stable, pure sine wave. Total harmonic distortion (THD) under ~3% is typical for inverters versus 9%+ for open-frame units. That matters for anything with a microprocessor: laptops, TVs, furnace control boards, CPAP machines, and modern refrigerators.

Head-to-head

Which type for your use case?

Fuel: gas, propane, or dual-fuel?

Most portables burn gasoline; dual-fuel models add propane. Propane stores indefinitely (gasoline goes stale in months without stabilizer), burns cleaner, and is easy to stockpile — at the cost of ~10% less power and shorter runtime per tank. For emergency backup you may use twice a decade, dual-fuel is worth the premium.

Safety, either type: outdoors only, 20+ feet from doors, windows, and vents, with a CO alarm inside. Never backfeed a panel — use a transfer switch or interlock kit installed by an electrician.

Worked example: cost per watt, and fuel over a long outage

Two typical purchases show the trade clearly. A 3,500 W inverter commonly sells around $900, about $0.26 per watt. A 3,500 W conventional open-frame commonly sells around $450, about $0.13 per watt. Same output, half the price per watt, exactly the gap described above. What the inverter buys back is fuel and quiet. At the light, varying loads of a real outage, a small inverter sips roughly 0.1 gallons per hour where an open-frame unit at a fixed 3,600 RPM burns closer to 0.4. Across a 24-hour outage day that is roughly 2.5 gallons against 9 or 10. Stretch the outage to three days and the inverter has burned about 7 gallons to the conventional unit's 28, a difference you can feel if you are rationing cans from the garage. Neither answer is wrong. The jobsite buyer who runs the unit six hours a month should take the cheap watts. The homeowner who runs it for three silent nights a year should take the inverter.

How to choose, in four steps

  1. Flag the sensitive loads. Anything with a microprocessor, a furnace control board, a CPAP, a laptop, goes on the sensitive list. A long sensitive list points to an inverter.
  2. Check your noise constraints. Campground quiet hours, close neighbors, and a baby asleep upstairs are all real specifications. If 70-plus decibels is a problem, the decision is made.
  3. Decide how you will store fuel. Gasoline needs rotation and stabilizer; propane keeps for years. If the generator sits untouched between storm seasons, dual-fuel earns its premium.
  4. Compare cost per running watt, not per peak watt. Divide the price by the running rating of each candidate. That is the honest price of the electricity you will actually use.

Common buying mistakes